GENERAL INFORMATION
3
WIRING
WARNING: Risk of electrical shock or electrocution.
This pool pump must be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable local codes and
ordinances. Improper installation will create an electrical hazard which could result in death
or damage to property. Always disconnect power to the pool pump at the circuit breaker
before servicing the pump. Failure to do so could result in death or serious injury to
serviceman, pool users or others due to electric shock.
1. Make sure all electrical breakers and
switches are turned off before wiring
motor.
2. Make sure that the wiring voltage
matches the motor voltage (230v or
115v). If they do not match the motor
will burn up.
3. Choose a wire size from Chart 1. When
in doubt use a heavier gauge (larger
diameter) wire. Heavier gauge will
allow the motor to run cooler and more
efficient.
4. Cut wires to the appropriate length so
they don’t overlap or touch when
connected to the terminal board.
5. Make sure all electrical connections are
clean and tight.
6. Permanently ground the motor using
the internal, green ground terminal
located on the inside of the motor
canopy or access plate, see Figure 1.
Use the correct wire size and type
specified by National Electrical Code.
Make sure the ground wire is connected
to an electrical service ground.
7. Bond the motor to the pool structure in
accordance with the National Electrical
Code. Use a solid NO.8 AWG or larger copper conductor. Run a wire from the brass external
bonding clamp, see Figure 1, to the pool bonding structure.
8. Connect the pump permanently to a circuit. Make sure no other lights or appliances are on
the same circuit.
NOTE: If the pump is installed below the water level of the pool, close return and suction lines prior to
opening hair and lint pot on pump. Make sure to re-open valves prior to operating.
Figure 1
External
Bonding
Clamp
Internal
Grounding
Screw
SUPPLY WIRE SIZES (AWG)
Size and Length by Horsepower
HP 115 Volts 230Volts
50 Ft. 100 Ft. 150 Ft. 50 Ft. 100 Ft. 150 Ft.
1/3 14 14 12 14 14 14
1/2 14 12 10 14 14 14
3/4 12 12 10 14 14 14
1 12 10 8 14 14 14
1-1/2 10 10 8 14 14 12
2 10 8814 12 12
3 ----- ----- ----- 12 12 10
Chart 1